Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
J Clin Med ; 13(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610691

RESUMO

Background: Older adults who have undergone surgery for oral tumors are at increased risk of impaired masticatory rhythm. This study investigated the correlations between masticatory rhythm, objective masticatory performance, and subjective masticatory performance as well as factors related to masticatory rhythm. Methods: The participants were 44 adults (24 men, 20 women; age range 42~90 years old) who had undergone maxillectomy, mandibulectomy, or glossectomy and were rehabilitated with a maxillofacial prosthesis. The number of functional contact teeth pairs was confirmed by intraoral examination. Chewing rate, cycle duration, coefficient of variation (CV) for cycle duration (reflecting the stability of masticatory rhythm), and mixing ability were measured simultaneously using a mastication movement rhythm tracking device during gum chewing. Maximum occlusal force was measured using the dental prescale system. Patients' perception of chewing ability was rated using a questionnaire. Results: The Spearman's rank correlation test revealed that mixing ability, patient-rated masticatory scores, cycle duration, CV for cycle duration, and maximum occlusal force showed significant correlations with chewing rate. Multiple linear regression analysis identified mixing ability and the CV for cycle duration as significant predictors of masticatory rhythm. Conclusions: Factors associated with a faster chewing rate were higher mixing ability and masticatory scores, greater maximum occlusal force, shorter cycle duration, and smaller CV for cycle duration. Stable masticatory rhythm and mixing ability are significant predictors of chewing rate. Poor masticatory performance and unstable masticatory rhythm can result in slower chewing and thus a higher risk of inadequate dietary intake.

2.
J Prosthodont ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566564

RESUMO

PURPOSE: The study aimed to compare the performance of four pre-trained convolutional neural networks in recognizing seven distinct prosthodontic scenarios involving the maxilla, as a preliminary step in developing an artificial intelligence (AI)-powered prosthesis design system. MATERIALS AND METHODS: Seven distinct classes, including cleft palate, dentulous maxillectomy, edentulous maxillectomy, reconstructed maxillectomy, completely dentulous, partially edentulous, and completely edentulous, were considered for recognition. Utilizing transfer learning and fine-tuned hyperparameters, four AI models (VGG16, Inception-ResNet-V2, DenseNet-201, and Xception) were employed. The dataset, consisting of 3541 preprocessed intraoral occlusal images, was divided into training, validation, and test sets. Model performance metrics encompassed accuracy, precision, recall, F1 score, area under the receiver operating characteristic curve (AUC), and confusion matrix. RESULTS: VGG16, Inception-ResNet-V2, DenseNet-201, and Xception demonstrated comparable performance, with maximum test accuracies of 0.92, 0.90, 0.94, and 0.95, respectively. Xception and DenseNet-201 slightly outperformed the other models, particularly compared with InceptionResNet-V2. Precision, recall, and F1 scores exceeded 90% for most classes in Xception and DenseNet-201 and the average AUC values for all models ranged between 0.98 and 1.00. CONCLUSIONS: While DenseNet-201 and Xception demonstrated superior performance, all models consistently achieved diagnostic accuracy exceeding 90%, highlighting their potential in dental image analysis. This AI application could help work assignments based on difficulty levels and enable the development of an automated diagnosis system at patient admission. It also facilitates prosthesis designing by integrating necessary prosthesis morphology, oral function, and treatment difficulty. Furthermore, it tackles dataset size challenges in model optimization, providing valuable insights for future research.

3.
J Oral Sci ; 66(2): 116-119, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38447982

RESUMO

PURPOSE: This study investigated the color stability of different commercially available silicone materials for facial prostheses upon exposure to everyday beverages. It was hypothesized that the beverages would not alter the color of the silicone under conditions simulating daily exposure. METHODS: Sixty specimens were fabricated using two materials - VST-50 and Silfy - and exposed to commercially available cold mineral water, tea, or coffee. Specimen color was evaluated on days 1 and 15. The color was measured with a spectrophotometer based on CIELab system and color differences were calculated as ΔE. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U test. RESULTS: The mean ΔE values after 15 days of exposure to mineral water, cold green tea, and coffee were 1.016, 3.480, and 3.636 for VST-50 and 0.440, 0.798, and 1.425 for Silfy, respectively. Both materials showed significant differences in color, and VST-50 showed a greater color change than Silfy, especially for coffee. CONCLUSION: Pigmented silicone elastomers have low color stability, leading to an overall color change in silicone prostheses when exposed to pigmented beverages. Color changes in such prostheses can be mitigated by selecting materials with better color stability to extend their longevity.


Assuntos
Prótese Maxilofacial , Águas Minerais , Elastômeros de Silicone , Cor , Café , Pigmentação em Prótese , Teste de Materiais , Bebidas
4.
Heliyon ; 10(4): e25529, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38370236

RESUMO

Purpose: Oral cancer often requires treatments like surgical intervention, involving surgical resection of lips and other facial parts. For those patients, prosthetic rehabilitation following surgery promotes social reintegration. This study explores the color stability of various commercially available silicone materials for facial prostheses when exposed to everyday beverages like coffee and tea. The hypothesis is that these beverages can induce color changes in silicones, simulating conditions of daily use. Material and methods: A total of 90 specimens were fabricated. There were 30 specimens deefor each of 3 nonpigmented silicone elastomers: Silfy, A-2186-F and VST-50 and were immersed in tea or coffee at drinking temperature and evaluated for color changes at time points of 0 h, 1 h, and 6 h. The color was measured with a colorimeter that used the CIE L*a*b* system and the color change ΔΕ was calculated to quantify the color change. Statistical analysis was performed by using the Kruskal-Wallis test, the Mann-Whitney U test, and the Wilcoxon signed-rank Test. The threshold for statistical significance was P < .05. Results: Color change was observed for each of the silicones exposed to the beverages (P < .05). The value of ΔE was significantly higher for A-2186-F compared with VST-50 and Silfy (P < .05 in all beverages at 6 h). The color of the elastomers progressively changed while immersed in the beverages over 6 h. The change in color was significantly greater for coffee compared with tea (P < .05). Conclusions: The color stability of nonpigmented silicone elastomers is inherently low, which contributes to the overall color change of silicone prostheses when they are exposed to beverages that contain pigments. The elastomer A-2186-F had greatest values of ΔE among the materials tested. Color changes of silicone prostheses can be lessened by selecting materials with consideration of color stability to improve their longevity and extend their period of use.

5.
J Prosthet Dent ; 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218707

RESUMO

Computer-aided design and computer-aided manufacturing technology has been applied to the fabrication of maxillary obturator frameworks, both directly and indirectly. However, with earlier techniques, it was not possible to accurately determine the position of the framework conforming to the palate, an issue that has been resolved in current fabrication methods. Using the patient's existing denture, prosthodontists can determine where the framework should be positioned in the defect area. This allows the obturator bulb to be hollowed, thereby reducing weight and making adjustment easier. The most appropriate position for the finish line can be determined by accurately establishing the arrangement of the artificial teeth as well as the most appropriate polishing surface morphology. In maxillofacial prosthetics, restoring proper articulation and the swallowing function through rehabilitation is important, and determining the proper palatal morphology enables good tongue movement and facilitates the restoration of adequate function. The lighter weight contributes to protecting the remaining teeth and improves patient comfort.

6.
J Prosthodont Res ; 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38281759

RESUMO

PURPOSE: To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints. METHODS: Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water. Flexural strength (FS), flexural modulus (FM), fracture toughness (FT), microwear depth (MD), degree of conversion (DC), water sorption (WSP), water solubility (WSL), color difference between non-aged and aged series (ΔE), and translucency (TP) were evaluated. All the evaluated properties other than FS and MD were analyzed by 1-way ANOVA and Tukey's post hoc analysis, while FS and MD were analyzed by Kruskal-Wallis's test and Bonferroni correction (α=0.05). RESULTS: BE10-80% revealed the lowest FS (P < 0.01 for BE10-0%, -20%, and -30%) and FM (P < 0.01, for all), while revealing the highest DC, WSP, WSL (P < 0.01 for all) and TP (P < 0.01 for all other than BE10-60%). BE10-50% showed the highest FT (P < 0.01 for all). BE10-50%, -60%, and -80% revealed significantly lower ΔE than others (P < 0.01) and lower MD than BE10-0% (P < 0.05). Regardless of the BE10 content, FS, FM, and FT decreased with aging. CONCLUSIONS: The number of ethylene oxide units affects the physical properties of additively manufactured occlusal splints. The higher number of ethylene oxide units in bis-EMA enhanced the microwear resistance, DC, WSP, WSL, color stability, and translucency, whereas it deteriorated the FS and FM.

7.
J Oral Sci ; 66(1): 88-90, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38030285

RESUMO

Mandibular deviation and rotation following mandibulectomy can significantly impact oral function and quality of life. The postoperative course of a 57-year-old patient who underwent mandibulectomy for oral cancer and findings over 11 years of follow-up observation to monitor changes in the mandibular position are described here. Based on the observations, it is important to raise awareness regarding the necessity of continued monitoring of mandible position and regular adjustments of prostheses for patients who have undergone mandibulectomy.


Assuntos
Osteotomia Mandibular , Neoplasias Bucais , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Mandíbula/cirurgia , Neoplasias Bucais/cirurgia
8.
J Clin Med ; 12(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38002714

RESUMO

Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman's ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.

9.
J Prosthet Dent ; 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37919132

RESUMO

STATEMENT OF PROBLEM: Trismus associated with maxillofacial defects resulting from tumor resection or radiotherapy can make dental treatment uncomfortable for patients. Using an intraoral scanner instead of making a conventional impression could help to make prosthetic rehabilitation more comfortable. However, limited information is available regarding the feasibility and accuracy of intraoral scanners for scanning mandibular defects. PURPOSE: The purpose of this in vitro study was to evaluate the feasibility and accuracy of using an intraoral scanner to digitize a cast of a mandibular defect under various simulated trismus conditions. MATERIAL AND METHODS: An intraoral scanner was used to scan the mandibular cast under different simulated degrees of trismus (mouth opening 10, 20, and 30 mm) and nontrismus (mouth opening 40 mm). The surface areas captured were compared. The datasets were loaded into a 3-dimensional (3D) evaluation software program and then superimposed for precision analysis and on reference data for trueness analysis. One-way analysis of variance was used to compare surface area captured, precision, and trueness of the measurement under the different mouth opening conditions (α=.05). RESULTS: The surface area for which 3D data were obtained by the intraoral scanner ranged from 3199.1 to 6161.6 mm2. The area differed significantly under all mouth opening conditions (P=.001), with a smaller scanned surface area captured in severe trismus (10 mm). Precision ranged from 0.032 to 0.056 mm, and trueness from 0.037 to 0.076 mm. No significant differences were seen in precision (P=.312), but significant differences were seen in trueness (P=.016) under all trismus conditions. CONCLUSIONS: Using an intraoral scanner appears feasible for digitizing mandibular defect casts with simulated mild and moderate trismus. The accuracy of the obtained data was clinically acceptable.

10.
ACS Appl Mater Interfaces ; 15(48): 55232-55243, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38014813

RESUMO

Promoting osseointegration is an essential step in improving implant success rates. Lithium has gradually gained popularity for promoting alkaline phosphatase activity and osteogenic gene expression in osteoblasts. The incorporation of lithium into a titanium surface has been reported to change its surface charge, thereby enhancing its biocompatibility. In this study, we applied anodization as a novel approach to immobilizing Li on a titanium surface and evaluated the changes in its surface characteristics. The objective of this study was to determine the effect of Li treatment of titanium on typical proteins, such as albumin, laminin, and fibronectin, in terms of their adsorption level as well as on the attachment of osteoblast cells. Titanium disks were acid-etched by 66 wt % H2SO4 at 120 °C for 90 s and set as the control group. The etched samples were placed in contact with an anode, while a platinum bar served as the counter electrode. Both electrodes were mounted on a custom electrochemical cell filled with 1 M LiCl. The samples were anodized at constant voltages of 1, 3, and 9 V. Scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM) results showed no significant differences in the topography. However, the ζ potentials of the 3 V group were higher than those of the control group at a physiological pH of 7.4. Interestingly, the adsorption level of the extracellular matrix protein was mostly enhanced on the 3 V-anodized surface. The number of attached cells on the Li-anodized surfaces increased. The localization of vinculin at the tips of the stretching cytoplasmic projections was observed more frequently in the osteoblasts on the 3 V-anodized surface. Although the optimal concentration or voltage for Li application should be investigated further, this study suggests that anodization could be an effective method to immobilize lithium ions on a titanium surface and that modifying the surface charge characteristics enables a direct protein-to-material interaction with enhanced biological adhesion.


Assuntos
Lítio , Titânio , Adesão Celular , Lítio/farmacologia , Adsorção , Titânio/farmacologia , Titânio/metabolismo , Comunicação Celular , Osteoblastos , Íons/metabolismo , Propriedades de Superfície , Microscopia Eletrônica de Varredura
11.
J Prosthodont Res ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37793819

RESUMO

PURPOSE: In this narrative review, we present the current applications and performances of artificial intelligence (AI) models in different phases of the removable prosthodontic workflow and related research topics. STUDY SELECTION: A literature search was conducted using PubMed, Scopus, Web of Science, and Google Scholar databases between January 2010 and January 2023. Search terms related to AI were combined with terms related to removable prosthodontics. Articles reporting the structure and performance of the developed AI model were selected for this literature review. RESULTS: A total of 15 articles were relevant to the application of AI in removable prosthodontics, including maxillofacial prosthetics. These applications included the design of removable partial dentures, classification of partially edentulous arches, functional evaluation and outcome prediction in complete denture treatment, early prosthetic management of patients with cleft lip and palate, coloration of maxillofacial prostheses, and prediction of the material properties of denture teeth. Various AI models with reliable prediction accuracy have been developed using supervised learning. CONCLUSIONS: The current applications of AI in removable prosthodontics exhibit significant potential for improving the prosthodontic workflow, with high accuracy levels reported in most of the reviewed studies. However, the focus has been predominantly on the diagnostic phase, with few studies addressing treatment planning and implementation. Because the number of AI-related studies in removable prosthodontics is limited, more models targeting different prosthodontic disciplines are required.

12.
Dent Mater J ; 42(5): 748-755, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37612058

RESUMO

We aimed to elucidate the effects of ultraviolet (UV) irradiation on the shear bond strength (SBS) between heat-cured polymethyl methacrylate (PMMA) and a Co-Cr-Mo alloy. Disk-shaped Co-Cr-Mo alloy prepared by casting were subjected to different UV treatment times (0, 15, and 30 min). To determine the effect of UV treatment on surface properties of the alloy, surface roughness, wettability, and chemical compositions were analyzed. To evaluate the SBS, cylindrical PMMA was bonded to the UV-treated alloy, and subsequently subjected to the SBS test after 24 h of storage at room temperature or following 10,000 thermal cycles (n=10/group). After the UV treatment, the surface roughness remained unchanged, but oxidation resulted in the surface exhibiting greater hydrophilic characteristics. The UV-treated group showed significantly higher SBS values than those of the non-treated group (p<0.001). These results suggested that UV treatment-mediated oxidation improved the bond strength between PMMA and Co-Cr-Mo alloy.

13.
J Prosthodont Res ; 2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37438109

RESUMO

PURPOSE: This study aimed to evaluate the influence of stress-relieving heat treatments on the metal-ceramic bond strength and fitness accuracy of selective laser melting (SLM)-fabricated Co-Cr alloy copings. METHODS: SLM-manufactured Co-Cr samples were stress-relieved at 750 (Ht-750) and 1150 °C (Ht-1150). The microstructure, surface roughness, metal-ceramic bond strength, marginal and internal fit, Vickers hardness, and residual stress were then compared with those of the non-heat-treated group (As-built). The results were analyzed using one-way ANOVA and post-hoc tests (Tukey's or Student's t test) (P = 0.05). RESULTS: The microstructure of the Ht-1150 samples had a brittle oxide layer and lower surface roughness, resulting in significantly lower bond strength values than those of the other groups. The As-built group exhibited significantly lower marginal gap values than the Ht-750 and Ht-1150 groups. Therefore, the post-heat treatments degraded the marginal fitness. The surface residual stress in all sample groups were compressive because of the sandblasting effect. The compressive stresses were larger in Ht-1150 than in As-built and Ht-750 owing to their low hardness values. CONCLUSIONS: Stress-relief annealing porcelain-fused-to-metal single crowns does not improve bond strength and degrades fitness accuracy because additional post-heat treatments induce thermal distortion. These findings are expected to facilitate the direct application of As-built SLM single crowns in dentistry to minimize post-manufacturing costs and time.

14.
J Prosthet Dent ; 2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37277237

RESUMO

An existing interim obturator can be reproduced as the definitive one using digital technology, with benefits for a patient with a maxillectomy. By digitally scanning the oral condition and the existing interim obturator, a definitive obturator, including a computer-aided designed and computer-aided manufactured metal framework, was fabricated and delivered to a patient with an anterior maxillectomy defect by following a combined digital and conventional workflow. This technique can hasten the adaptation of the patient to the new obturator and ensure a more comfortable and safer clinical procedure.

15.
J Prosthet Dent ; 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37330360

RESUMO

This clinical report describes a novel approach based on digital technology to fabricate a maxillofacial prosthesis for a 90-year-old woman with severe trismus who had undergone maxillectomy on the right side. The approach was safe, rapid, and less burdensome on this elderly patient, and the storage and communication of intraoral and maxillofacial prosthesis data without temporal and spatial constraints was helpful. A combination of digital and analog technology provided a maxillofacial prosthesis that improved the quality of life of this elderly patient with head and neck cancer and severe trismus.

16.
Inflamm Regen ; 43(1): 32, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37340499

RESUMO

BACKGROUND: Bone defects remain a challenge today. In addition to osteogenic activation, the crucial role of angiogenesis has also gained attention. In particular, vascular endothelial growth factor (VEGF) is likely to play a significant role in bone regeneration, not only to restore blood supply but also to be directly involved in the osteogenic differentiation of mesenchymal stem cells. In this study, to produce additive angiogenic-osteogenic effects in the process of bone regeneration, VEGF and Runt-related transcription factor 2 (Runx2), an essential transcription factor for osteogenic differentiation, were coadministered with messenger RNAs (mRNAs) to bone defects in the rat mandible. METHODS: The mRNAs encoding VEGF or Runx2 were prepared via in vitro transcription (IVT). Osteogenic differentiation after mRNA transfection was evaluated using primary osteoblast-like cells, followed by an evaluation of the gene expression levels of osteogenic markers. The mRNAs were then administered to a bone defect prepared in the rat mandible using our original cationic polymer-based carrier, the polyplex nanomicelle. The bone regeneration was evaluated by micro-computerized tomography (µCT) imaging, and histologic analyses. RESULTS: Osteogenic markers such as osteocalcin (Ocn) and osteopontin (Opn) were significantly upregulated after mRNA transfection. VEGF mRNA was revealed to have a distinct osteoblastic function similar to that of Runx2 mRNA, and the combined use of the two mRNAs resulted in further upregulation of the markers. After in vivo administration into the bone defect, the two mRNAs induced significant enhancement of bone regeneration with increased bone mineralization. Histological analyses using antibodies against the Cluster of Differentiation 31 protein (CD31), alkaline phosphatase (ALP), or OCN revealed that the mRNAs induced the upregulation of osteogenic markers in the defect, together with increased vessel formation, leading to rapid bone formation. CONCLUSIONS: These results demonstrate the feasibility of using mRNA medicines to introduce various therapeutic factors, including transcription factors, into target sites. This study provides valuable information for the development of mRNA therapeutics for tissue engineering.

17.
Polymers (Basel) ; 15(9)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37177280

RESUMO

Additive manufacturing is an emerging technology that has been successfully used in dentistry for denture fabrication. However, the conventional issue of tooth debonding exists in additively manufactured dentures. In this study, we investigated the physical properties of conventional teeth attached to a heat-cured denture base material compared to additively manufactured tooth-coloured materials attached to denture base-coloured materials in a printed monolithic unit. We designed a model consisting of a tooth attached to a cylindrical base to fabricate the additively manufactured group and the conventional group. All groups were tested for fracture load before and after thermocycling, water sorption, solubility, and shape accuracy. The Mann-Whitney U test was used for statistical analysis. The fracture load of the additively manufactured group was significantly higher than that of the conventional group after thermocycling (p = 0.019). The water sorption of the conventional group was significantly lower than that of the additively manufactured group (p = 0.000), whereas there was no significant difference in the water solubility between them (p = 0.192). The shape accuracy of the additively manufactured group was significantly better than that of the conventional group (p < 0.05). In conclusion, additive monolithic manufacturing technology may provide an alternative way to enhance the fracture load between the teeth and denture bases.

18.
J Mech Behav Biomed Mater ; 142: 105873, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37119722

RESUMO

This study aimed to evaluate the effect of splinting material type and material location on the force resistance of splinted periodontally compromised teeth with hypermobility. Extracted teeth including the target tooth (maxillary second premolar) and its adjacent teeth were placed into the alveolar sockets of a dental arch model via artificial periodontal ligaments made of elastic impression material. Three different experimental models with varied target tooth mobility including Periotest® values (PTVs) of 20, 30, and 40 were fabricated (named models #20, #30, and #40, respectively). For each experimental model, the force resistance of tooth splinting was tested using the following four materials: everStick PERIO (glass fiber reinforcement: GFR), FORESTAFLEX (braided stainless steel: BSS), Ortho-FlexTech (stainless steel chain: SSC), and Super-Bond (MMA-based resin cement: MRC). The evaluated measures were the PTV after tooth splinting and the required load to cause tooth displacements of 0.05 mm and 0.10 mm in the vertical and lateral directions, respectively. The splinting material type and material location as well as the original PTV of target the tooth significantly affected all the evaluated measures (p < 0.001). MRC revealed the significantly highest force resistance of tooth splinting regardless of material location in each experimental model and was followed by GFR. The PTVs of splinted teeth were comparable to those of adjacent anchor teeth in models #20 and #30 when using GFR, while that was comparable in model #40 when using MRC. Meanwhile, the load causing certain tooth displacement showed a similar tendency to previous-reported data with healthy teeth in model #20 when using GFR, while that showed a similar tendency in models #30 and #40 when using MRC. Overall results concluded that splinting material type and location play a role in the resistance against the deflection force of splinted periodontally compromised hypermobile tooth. It was noted that MRC provided the highest resistance against the deflection force of splinted teeth regardless of material location whereas GFR maintained the physiologically considered tooth mobility.


Assuntos
Mobilidade Dentária , Humanos , Aço Inoxidável , Ligamento Periodontal , Dente Pré-Molar
19.
J Mech Behav Biomed Mater ; 142: 105799, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37028121

RESUMO

Although additive manufacturing has been widely applied for occlusal splint (OS) fabrication, it is still unclear whether 3D printing system and post-curing atmosphere would play a role in the wear resistance of additive-manufactured OS. Therefore, the aim of this study was to evaluate the effect of 3D printing system (liquid crystal display (LCD) and digital light processing (DLP)) and post-curing atmosphere (air and nitrogen gas (N2)) on the wear resistance of hard and soft OS materials for additive-manufactured OSs (KeySplint® Hard and Soft). The evaluated properties were microwear (by two-body wear test) and nano-wear resistances (by nanoindentation wear test) as well as flexural strength and flexural modulus (by three-point bending test), surface microhardness (by Vickers hardness test), and nanoscale elastic modulus (reduced elastic modulus) and nano surface hardness (by nanoindentation test). For the hard material, the surface microhardness, microwear resistance, reduced elastic modulus, nano surface hardness, and nano-wear resistance were significantly affected by the printing system (p < 0.05), while all the evaluated properties except flexural modulus were significantly affected by the post-curing atmosphere (p < 0.05). Meanwhile, both the printing system and post-curing atmosphere significantly affected all the evaluated properties (p < 0.05). The specimens additive-manufactured by DLP printer tended to show higher wear resistance in the hard material groups and lower wear resistance in the soft material groups when compared to those by LCD printer. The post-curing at N2 atmosphere significantly enhanced the microwear resistance of hard material groups additive-manufactured by the DLP printer (p < 0.05) and soft material groups additive-manufactured by the LCD printer (p < 0.01), while it significantly enhanced the nano-wear resistance of both hard and soft material groups regardless of the printing system (p < 0.01). It can be concluded that 3D printing system and post-curing atmosphere affect the micro- and nano-wear resistance of tested additively manufactured OS materials. In addition, it can be also concluded that the optical printing system providing higher wear resistance depends on the material type, and using nitrogen gas as a protection gas during post-curing enhances the wear resistance of tested materials.


Assuntos
Placas Oclusais , Impressão Tridimensional , Teste de Materiais , Resistência à Flexão , Nitrogênio , Propriedades de Superfície
20.
J Clin Med ; 12(7)2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37048805

RESUMO

As society ages, it is important to understand the prevalence of dementia and the difficulties of inserting prostheses in patients with maxillofacial defects in order to clarify issues in supportive care. We screened 183 patients for dementia using the revised Hasegawa's dementia scale (HDS-R) at the Clinic for Maxillofacial prosthetics, Tokyo Medical and Dental University, and investigated age and sex differences in HDS-R score. We asked 47 of the 183 participants about the difficulty of inserting a maxillofacial obturator prosthesis and collected subjective comments, information about the prosthesis, and data from five assessments. Multiple regression analysis was used to reveal factors associated with insertion difficulty. Overall, 8.7% of the participants were judged to have possible dementia. Men were more likely than women to have possible dementia, and the risk increased with age. Of the 47 participants, 26 reported difficulty inserting their prosthesis, 12 of whom attributed it to their oral defect. Fourteen patients advised following doctor's instructions to practice insertion in order to become accustomed to it. A lower HDS-R score had a significant impact on insertion difficulty. Cognitive function and difficulty inserting maxillary obturator prostheses should be considered in the provision of continuous supportive care to patients with maxillary defects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...